MAGNUM 6500
®
/ 7500
®
CORN/WOOD PELLET FURNACE
THIS APPLIANCE HAS BEEN TESTED AND APPROVED TO CSA B 366.1-M91-CAN/USA & UL 391-99
WARNING: THIS INSTRUCTION MANUAL MUST BE SAVED FOR FUTURE REFERENCE
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS CORN/WOOD PELLET
BURNING FURNACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR EVEN DEATH.
REFER TO ADDITIONAL MARKINGS ON APPLIANCE FOR ADDITIONAL INSTRUCTIONS
IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory.
When you call have your serial number, purchase date, who installed the unit and a list of questions.
This appliance must be installed by a licensed/trained factory approved installer
AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE
INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY
CONSEQUENTIAL DAMAGE(S).
Disclaimer Notice: No guarantee is made regarding the heating capacity of this unit. The actual area that this unit will heat depends on
factors such as fuel quality, fuel moisture, installation configuration, venting and fresh air configuration, operational practices, conditions of
the building, heat loss, type of construction, amount and type of insulation, type of air movement, and the location of the Furnace.
AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350
Web Site: www.magnumheat.com
Rev. date 01/01/08
9 When installing your Magnum 6500/7500 Corn/Wood Pellet Furnace, particular attention needs to be
made in regards to fire protection. If the unit is not properly installed, a house fire may result. For your
safety, follow the installation and operation instructions provided, and if a question arises contact local
building or fire officials about restrictions and installation requirements in your area.
9 Read the operations and fuel section of this manual before plugging in your unit.
9 Always unplug the unit before attempting any service work.
9 Do not connect the unit to a chimney flue already serving another appliance.
9 When installing the chimney pipe to the unit, it is important to remember that the unit operates on a
negative pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings
must be airtight. (proper venting practices must be followed. Consult with a venting professional)
9 Ashes must be disposed of in a metal container with a tight fitting lid. Do not let ashes build up in ashpan.
9 All minimum clearances to combustibles must be followed. Ductwork clearances must be maintained.
9 The Magnum 6500/7500 Corn/Wood Pellet Furnace is tested for operation with 14% or less moisture
corn or with wood pellets with an ash content of no more than 3%. It is recommended that Corn with
11-12% moisture or wood pellets with an ash content of 1% or less be used for efficient operation of
this unit. Corn over 12% moisture has a lower BTU value and will be hard to burn on the lower
settings. Fuel over 12% moisture will dramatically reduce the heating ability of this appliance.
9 It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you
the same fuel each time that you purchase. It is recommended that you purchase your entire heating season
supply of fuel at one time so that the fuel will be the same.
9 A voltage surge protector or ground fault outlet is required for this unit. The warranty on the
circuit board will be voided if proper surge protection is not installed before operating this unit
9 Proper voltage, polarity and grounding must be assured for appliance to operate correctly. Consult
with your electrician before operating this appliance to assure electrical is proper.
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions
Vista de página 0
1 2 3 4 5 6 ... 44 45

Resumo do Conteúdo

Página 1 - CORN/WOOD PELLET FURNACE

MAGNUM 6500® / 7500® CORN/WOOD PELLET FURNACE THIS APPLIANCE HAS BEEN TESTED AND APPROVED TO CSA B 366.1-M91-CAN/USA & UL 391-99 WARNING:

Página 2

10 The Magnum 6500/7500 Corn/Wood Pellet Furnace may be installed on a combustible floor, with proper floor protection, or on a masonry hearth. T

Página 3 - SPECIFICATIONS

11 It is required that only authorized licensed installers install your Magnum furnace. The following installation guidelines must be followed to e

Página 4 - SAFETY STEPS

12GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN, CONT…… 1) Determine the “equivalent pipe length” for each component used according to the comparis

Página 5

13GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN, CONT…… CHIMNEY AND VENTING (4” diameter is recommended) Chimney required for the Magnum Corn Furna

Página 6

14 OUTSIDE MAKE-UP AIR FOR COMBUSTION IS REQUIRED ON ALL INSTALLATIONS 1) For all Furnace installations, it is REQUIRED that the furnace combustio

Página 7

15 The Magnum 6500/7500 Corn/Wood Pellet Furnace may be installed as follows: 1) A Stand-Alone System (Shop Furnace with ductwork coming off the

Página 8 - WOOD PELLETS

16 WARNING: Improper operation of the unit and Creosoting will occur if exterior venting is not enclosed in an insulated chase way. Storm Collar 3

Página 9 - CLEARANCE TO COMBUSTIBLES

17 Storm Collar Design system to accommodate the cold air return (app. 24” of room needed)

Página 10

18 Shop Plenum (CF30) Shop Plenum CF30 STAND ALONE OR SHOP FURNACE The Magnum 6500/7500 Corn/Wood Pellet Furnace may be installed as a stand-alon

Página 11

19 Add-On Furnace (Supplementary Heat installation) To install the Magnum 6500/7500 as an “add-on furnace” first set the unit along side the existin

Página 12 - MAXIMUM

2 TABLE OF CONTENTS PAGE INTRODUCTION & SPECIFICATIONS………….……

Página 13

20 3” or 4” L vent Magnum 6500/7500 Furnace The Magnum with independent ductingMake sure that when the warm air plenum is installed that there is a

Página 14

21 Your Magnum 6500/7500 Corn/Wood Pellet Furnace comes to you with the glass door installed in place, ready for use. The glass is surrounded on

Página 15 - WARNING

22 Front view Side view showing heat exchanger rod operation A

Página 16 - 3” clearance (or venting

23 The Magnum 7500 Corn and Wood Pellet Furnace comes standard with a combustion enhancement system built into the firepot. This system enables th

Página 17 - Design system to

24 9 Turn the Fuel Stirrer knob to the number 1 setting and let it rotate a couple turns to stir the firestarter and wood

Página 18 - Shop Plenum

25 Startup When the circuit board is energized (unit plugged in) there is a 15 second purging of the auger tube to allow fuel to enter the firepot.

Página 19

26 A proper draft setting is crucial to the successful burning of solid fuels. Draft refers to the amount of air flowing through the burn chamber

Página 20 - Magnum 6500/7500

27 9 You might need to stir the fire occasionally during startup to get the fire going really well. Opening the door wi

Página 21

28 Startup When the circuit board is energized (unit plugged in) there is a 15 second purging of the auger tube to allow fuel to enter the firepot.

Página 22 - STOVE CONTROLS

29 A proper draft setting is crucial to the successful burning of solid fuels. Draft refers to the amount of air flowing through the burn chamber

Página 23

3DEAR VALUED MAGNUM 7500 OWNER, We appreciate your decision to help preserve our precious environment by purchasing the Magnum 6500 or the 7500 Corn

Página 24

30 DAILY MAINTENANCE 9 Surfaces on the front of the furnace will be extremely hot during operation. Always wear heat resistant gloves to perform

Página 25 - CIRCUIT BOARD FUNCTIONS

31SPECIAL CLEANING/OPERATIONAL/INSTALLATION INSTRUCTIONS: CREOSOTE – FORMATION AND NEED FOR REMOVAL: With the low operating temperatures of the Magn

Página 26

32WEEKLY MAINTENANCE 9 Set the furnace on high fire. Open the draft to 100% and allow the furnace to burn for 15 minutes. Resume desired heat and

Página 27

33 SPRING CLEANING: When the heating season is over make sure that you clean out all of the fuel in the hopper, firebox

Página 28

34 9 The Magnum 6500/7500 can be installed with and operated by a wall-mounted thermostat. However, a wall thermostat is not provided with the fu

Página 29

35Magnum 7500 Wiring Diagram The High limit control is pre-set and does not need to be adjusted. If the furnace is overheating consult your HVAC

Página 30 - MAINTENANCE INSTRUCTIONS

36 Magnum 6500 Wiring Diagram The High limit control is pre-set and does not need to be adjusted. If the furnace is overheating consult your HV

Página 31

37 PROBLEM CAUSES SOLUTIONS ? Fire burns with a lazy, orange flame and/or fuel builds up in the firepot and excessive (builds up in a hour or

Página 32 - WEEKLY MAINTENANCE

38PROBLEM CAUSES SOLUTIONS ? Fire goes out or stove shuts down automatically. ♦ Hopper is empty. ♦ Fuel is not feeding. ♦ High limit temper

Página 33 - AUTOMATIC SAFETY FEATURES

39PROBLEM CAUSES SOLUTIONS ? Blower will not operate. ♦ No power to stove. ♦ Blower is defective ♦ Ductwork is inadequate and

Página 34 - THERMOSTAT INSTALLATION

4 When you receive your Magnum Corn/Pellet Furnace, be careful to inspect all parts and components to make sure that nothing was damaged or lost i

Página 35 - Magnum 7500 Wiring Diagram

40PROBLEM CAUSES SOLUTIONS Fuel burns off to quickly, have difficulty keeping a pilot fire. Air shutter is open to far. Over drafting on a vertica

Página 36 - Magnum 6500 Wiring Diagram

41IMPORTANT: Electrical work must be performed by an authorized technician. WARNING: This section is only for qualified technicians. If the low

Página 37 - TROUBLE SHOOTING GUIDE

42DRAFT SLIDE GATE ADJUSTMENT (Optional equipment) If installing and using the Draft Slide Gate: The slide gat

Página 38

43 ORDER # DESCRIPTION AFP24 Spring Handle, Gold, Heat Exchanger Rod CF02 Ash Pan Assembly, MagnuM 7500 CF06 Firepot, Stainless Steel, Corn/Biom

Página 39

44 5 YEAR PRO-RATED LIMITED WARRANTY model 6500 & 7500 furnaces This warranty is issued by American Energy Systems, Inc. (Manufacturer) and ext

Página 40

45SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED

Página 41 - TECHNICIAN

5The Magnum 6500/7500 will burn high ash content fuels but will require additional maintenance/cleaning. 9 A working smoke detector must be instal

Página 42 - DRAFT SLIDE GATE ADJUSTMENT

69 DO NOT USE DUCT ELBOWS HAVING AN INSIDE RADIUS OF LESS THAN 6 INCHES (150MM) ON THE (oil, electric, gas) furnaces. 9 DO NOT CONNECT DUCTWORK SO

Página 43

7 Unlike petroleum and natural gas products, solid fuels such as corn and wood pellets create ash as the fuel is burned. Even with the highly eff

Página 44

89 There are many varieties of corn grown around the world. Each variety has unique characteristics including the shape and size of the kernel. Yo

Página 45 - SERVICE RECORD

9 CLEARANCE TO COMBUSTIBLES Back 1” Supply Plenum 2” Side 1” Class L Vent 3” Corner 1” Front 48”